Overview
ZJHQ/ZJHX pneumatic diaphragm three-way control valves feature cylindrical thin-wall window-type plug guiding, unlike the bushing guiding of a plunger-type plug. Fitted with a multi-spring actuator, they offer simple construction, light weight, small size and easy assembly and disassembly. They are widely used to precisely maintain process parameters such as pressure, flow rate, temperature and level of gases and liquids at set values. The converging type merges two fluids into one, while the diverging type splits one fluid into two streams. Nominal pressure ratings: PN16, PN40 and PN64; nominal diameters: DN25 to DN300. Fluid temperature range: -60 °C to +450 °C. Leakage class IV. Flow characteristics: linear and parabolic.
Main Parts Materials and Recommended Temperature Range
|
Part Name
|
Material
|
Temperature Range
|
|---|---|---|
| Valve Body, Upper & Lower Bonnets | HT200 | -20 ~ 200°C |
| ZG230-450 | -40 ~ 450°C | |
| ZG1Cr18Ni9Ti | -250 ~ 550°C | |
| Plug, Seat & Stem | 1Cr18Ni9 | -250 ~ 550°C |
| Gasket | Rubber-asbestos sheet | |
| Stainless steel spiral wound gasket | ||
| Packing | PTFE | |
| Upper & Lower Diaphragm Plates | A3 steel plate | |
| Diaphragm | 35CrMoA | |
| 35, A3 | ||
| Yoke & Top Plate | HT200 | |
| Compression Spring | 60Si2Mn | |
| Corrugated Diaphragm | 5806 rubber with 480D nylon 66 mesh fabric |
Control Valve Technical Parameters
|
Seat Diameter (mm)
|
Converging
|
25
|
32
|
40
|
50
|
65
|
80
|
100
|
125
|
150
|
200
|
250
|
300
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Diverging
|
25
|
32
|
40
|
50
|
65
|
80
|
100
|
125
|
150
|
200
|
250
|
300
|
|
| Rated Flow Coefficient Kv | Converging | 8.5 | 13 | 21 | 34 | 52 | 85 | 125 | 210 | 340 | 535 | 800 | 1260 |
| Diverging | 8.5 | 13 | 21 | 34 | 52 | 85 | 125 | 210 | 340 | 535 | 800 | 1260 | |
| Nominal Pressure (MPa) | 1.6 4.0 6.4 | ||||||||||||
| Stroke (mm) | 16 | 25 | 40 | 60 | 100 | ||||||||
| Flow Characteristic | Linear | ||||||||||||
| Medium Temperature (°C) | -20 ~ 200 °C, -40 ~ +250 °C (normal temperature type), -40 ~ 315 °C (medium temperature type) | ||||||||||||
| Flange Dimensions | Cast iron flange dimensions per JB78-59; cast steel flange dimensions per JB79-59 | ||||||||||||
| Flange Type | Sealing face type per JB77-59: cast steel flanges with smooth type; cast iron flanges with concave-convex type | ||||||||||||
| Body Material | HT200, ZG230-450, ZG1Cr18Ni9 | ||||||||||||
| Plug Material | 1Cr18Ni9 | ||||||||||||
| Bonnet Type | Plain (normal temperature type), cooling-fin (medium temperature type) | ||||||||||||
| Rangeability R | 30:1 | ||||||||||||
| Air Supply Connection | M16×1.5 | ||||||||||||
Actuator Technical Parameters
|
Model
|
ZHA(B)-3
|
ZHA(B)-4
|
ZHA(B)-5
|
ZHA(B)-6
|
|---|---|---|---|---|
| Effective Area (cm²) | 400 | 630 | 1000 | 1600 |
| Stroke (mm) | 25 | 40 | 60 | 100 |
| Spring Range (kPa) | 20 ~ 100; 40 ~ 200; 20 ~ 60; 60 ~ 100; 80 ~ 240 | |||
Performance Specifications
|
Item
|
Without Positioner
|
With Positioner
|
||
|---|---|---|---|---|
| Basic Error (%) | ±6 | ±1.5 | ||
| Hysteresis (%) | 5 | 1.5 | ||
| Dead Band (%) | 4 | 0.6 | ||
| End Point Deviation (%) | Air-to-close | Starting point | ±2.5 | ±1.5 |
| End point | ±6.0 | |||
| Air-to-open | Starting point | ±6.0 | ||
| End point | ±2.5 | |||
| Rated Stroke Deviation (%) | ±2.5 | |||
| Allowable Leakage (L/h) | 10-3 × rated valve capacity | |||
Note: A positioner is generally required.
Allowable Differential Pressure
|
Supply Pressure (MPa)
|
Spring Pressure (kPa)
|
25
|
32
|
40
|
50
|
65
|
80
|
100
|
125
|
150
|
200
|
250
|
300
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.14 | 20-100 | 1220 | 750 | 500 | 300 | 300 | 200 | 120 | 120 | 80 | 50 | 50 | 25 |
Optional accessories: positioner, handwheel mechanism, air filter regulator, etc.
Overall Dimensions
|
Nominal Diameter (mm)
|
25
|
32
|
40
|
50
|
65
|
80
|
100
|
125
|
150
|
200
|
250
|
300
|
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| L (mm) | PN1.6 MPa | 185 | 200 | 220 | 250 | 275 | 300 | 350 | 410 | 450 | 550 | 635 | 720 |
| PN4.0 MPa | 190 | 210 | 230 | 255 | 285 | 310 | 355 | 425 | 460 | 560 | 660 | 740 | |
| PN6.4 MPa | 200 | 210 | 235 | 265 | 295 | 320 | 370 | 440 | 475 | 570 | 670 | 770 | |
| H1 (mm) | PN1.6 MPa | 140 | 150 | 160 | 180 | 200 | 220 | 220 | 256 | 278 | 322 | 540 | 612 |
| PN4.0 MPa | 150 | 160 | 170 | 190 | 220 | 232 | 256 | 295 | 313 | 372 | 540 | 612 | |
| PN6.4 MPa | 160 | 170 | 180 | 200 | 220 | 242 | 266 | 300 | 318 | 382 | 540 | 612 | |
| H (mm) | Standard type | 435 | 441 | 465 | 480 | 584 | 585 | 575 | 762 | 772 | 792 | 1203 | 1234 |
| Cooling-fin type | 565 | 571 | 595 | 610 | 631 | 748 | 738 | 961 | 971 | 989 | 1525 | 1554 | |
| D (mm) | 285 | 360 | 470 | ||||||||||
| Weight (kg) | 72 | 75 | 81 | 88 | 135 | 158 | 190 | 262 | 322 | 450 | 550 | 600 | |
Note: Diverging valves with nominal diameter below DN80 are replaced by converging valves of the same size.